SX8R Bus Coupler Module

Streamlined Communication with Multiple Open Network Support

Revolutionary SX8R Series Bus Coupler Module


The new SX8R Series Bus Coupler Module is designed to revolutionize remote I/O solutions, offering unparalleled flexibility and performance. It supports multiple protocols for seamless integration with diverse systems. Customers can choose from over 40 existing IDEC FC6A MicroSmart PLC I/O modules, supporting a wide range of discrete and analog signals. Expand up to 15 modules (480 discrete points, 120 analog inputs, and 60 analog outputs), while the maximum number of SX8R nodes capacity varying by host unit and protocol. The user-friendly configuration tool saves all settings, eliminating the need for repeated configurations. Additionally, the SX8R Series operates reliably within a broad temperature range of -25°C to 65°C, ensuring robust performance in various environments. Built for endurance, the SX8R is backed by an industry-leading three-year warranty.





Key Features


 

With support for EtherNet/IP, Modbus TCP, and CC-Link IE Field Basic, our Bus Coupler offers unparalleled flexibility and compatibility with various industrial protocols. Learn More

 

Designed to perform in extreme conditions, the Bus Coupler operates efficiently in temperatures ranging from -20 to 65 ˚C, making it ideal for a variety of industrial environments. Learn More

 

Choose from a wide array of IDEC FC6A MicroSmart PLC I/O modules to customize your system according to specific application requirements, enhancing both functionality and scalability.  Learn More


 

Backed by a 3-year warranty, our Bus Coupler guarantees long-term reliability and peace of mind, underscoring our commitment to quality and customer satisfaction.

 

Built with a modular architecture, our system allows for easy scalability and customization to meet the specific needs of your application. Expand your I/O capacity effortlessly as your operations grow. Learn More

 

Simplify setup and maintenance with our intuitive configuration tool, designed to streamline the process and reduce downtime. Learn More

 

The Push-In Terminal significantly reduces wiring and maintenance time, offering a fast and straightforward installation process without the need for specialized tools. 


 

Class I Div 2, CE,  UKCA, UL/cUL approved and RCM certified for global usage. Learn More

Downloads


Remote I/O systems reduce maintenance time, wiring materials, and cable laying in distributed control, as well as decrease the total cost by downsizing the control panel.

The impact of signal weakening and background noise caused by long-distance transmission is minimized. Learn More

適用アプリケーション


Compatible with major open networks


Supports EtherNet/IP (adapter), Modbus TCP (server), CC-Link IE Basic (slave station)

SX8R-img04.jpg

EP1824-0-SX8R-1.jpg

Simultaneous Communication with Two Master Stations


A controller and monitoring device can be connected at the same time, even on different networks. You can build a control and monitoring system with a single remote I/O coupler.

EP1824-0-SX8R copy.jpg

*Simultaneous connection of EtherNet/IP and CC-Link IE Field Basic is not possible.


Build a system with flexible I/O modules


Paired with IDEC's MicroSmart FC6A I/O modules, it facilitates the seamless creation of a remote I/O system. A wide variety of MicroSmart FC6A I/O modules (48 models) can be used to build an efficient remote I/O system.


Digital input module

8 models

8, 16, 32 points

Digital output module

16 models

Tr. sync / Tr. source / Relay

8, 16, 32 points

Digital mixed I/O module

4 models

Relay

8, 24 points

Analog input module

8 models

Voltage/Current / Thermocouple / RTD

2, 4, 8 points

Analog output module

4 models

Voltage/Current

2, 4 points

Analog I/O module

4 models

Voltage / Current / Thermocouple / RTD

3, 6 points

Temperature sensor input module

4 models

Thermocouple / Thermistor

4, 8 points


Connect up to 15 I/O modules


Maximum of 7 I/O modules can be connected.
Additional 8 expansion modules can be connected by installing the expansion interface module.

SX8R特長


For various applications with a wide temperature range

Secure and reliable hardware



Wide operating temperature range

Suitable for use in hot and cold environments ranging from -25°C to +65°C.

I/O module

Wide range of IDEC MicroSmart FC6A modules compliant with various safety standards. Various relay modules also available.


Baseless structure

Minimal space is needed as no base unit installation is required. I/O modules can be added after installation, enabling flexibility.

VIDEO



Easy configuration and monitoring with a dedicated software


software-EN-2.gif

SX8R-img14.png

The dedicated PC configuration tool "SX8R Configurator" (free) is available for configuring communication and module settings. Drag and drop functionality allows easy configuration of I/O modules.
The ON/OFF status of digital I/O modules and the current values, set values, and error information of analog I/O modules can be monitored remotely.

OS: Windows 11, Windows 10
CPU: 1.0GHz or higher
Memory: 2GB or higher
Environment: Microsoft.NET 6.0 or later

Part Numbers


Quantity: 1



Terminal

Power

Communication protocol

Part No.

Ethernet port 1

Ethernet port 2

SX8R-img16.jpg

Push-in

24V DC

Modbus TCP communication (server)

EtherNet/IP communication (adapter)

CC-Link IE Field Basic communication (slave station)

Maintenance communication (server)

Maintenance communication (server)

SX8R-ECB4

Screw

SX8R-ECB1



Applications


Wastewater Treatment

Food / Packaging Machinery

Conveyor Equipment / Conveyor

HVAC(air conditioning control, chiller market)

Machine Tools

Irrigation and Agriculture




REQUEST A DEMO